DWL@DWL10000302956
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
2.5.5.0 | * | 27.07.2017 | 2 MB | EXE | AS2.6_HW_X20BC1083.exe | |
Popis |
V2.6 HW Upgrade (X20BC1083) Revision information X20BC1083 Version 2.5.5.0: ID: 544065 NetX Firmware update bug fix Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(420), 1\8808_2.fw(420), 1\8808_3.fw(420) Version 2.5.4.0: ID: 540305 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(419), 1\8808_2.fw(419), 1\8808_3.fw(419) Version 2.5.3.0: ID: 523460 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(417), 1\8808_2.fw(417), 1\8808_3.fw(417) Version 2.5.2.0: ID: 479550 / Support ID: 400191269 X20BC1083 with disabled netX modules is not booting - Error 32162 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 482985 Module documentation revised Data sheet V2.42 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 485140 / Support ID: 400189834 X20IF1091-1 + X20BC1083 + X20IF10E1-1 cause service of PLC and error 30023 in logger Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 493875 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\8808_1.fw(415), 1\8808_2.fw(415), 1\8808_3.fw(415) Version 2.5.0.0: ID: 456040 / Support ID:400169536 Restart of the netX interface card If PLK-failure the netX interface card is reset by the Bus Controller Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468020 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468025 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468030 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468520 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\8808_1.fw(413), 1\8808_2.fw(413), 1\8808_3.fw(413) Version 2.3.0.0: ID: 420490 / Support ID: 400149579 X20IF1061-1: Cyclic statusbits wrong when cable is disconnected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 450165 / Support ID: 400166011 AS4.X hwx modifications in some cases, a problem could occur in the AS with the 2. port of the BC Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 460095 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460215 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(411), 1\8808_2.fw(411), 1\8808_3.fw(411) Version 2.2.0.0: ID: 439090 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439195 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(400), 1\8808_2.fw(400), 1\8808_3.fw(400) Version 2.1.0.0: ID: 396390 / Support ID: 400138162 Error in small netX configurations In small netX configurations (smaller than the MTU configured in POWERLINK), it was not possible to transfer the configuration. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 402415 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules wereremoved or added. A new handshake between Automation Runtime and firmware wasimplemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(300), 1\8808_2.fw(300), 1\8808_3.fw(300) Version 2.0.0.0: ID: 374125 / Support ID: 400123625 X20BC1083: Update error X20IF10E3-1 after configuration change If the configuration of a X20IF10E3-1 that is connected to a X20BC1083 POWERLINK X2XLink bus controller was changed, there were occasionally update problems. The logbook filled with warning 20980 and the buscontroller was reseting cyclically. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 385855 / Support ID: 400095196 Streaming-Support for IF-Modules on X20BC1083 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 390265 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(210), 1\8808_2.fw(210), 1\8808_3.fw(210) Version 1.3.6.0: ID: 326250 The upgdate of the X2IF1043-1 on the X20BC1083 doesn't work Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(171), 1\8808_2.fw(171), 1\8808_3.fw(171) Version 1.3.5.0: ID: 310775 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configurationdescription changed: Yes Firmware changed: No ID: 310780 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- UpgradeVersion 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(168),1\8808_2.fw(168), 1\8808_3.fw(168) Version 1.3.4.0: ID: 304570 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restoredcommunication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(167), 1\8808_2.fw(167), 1\8808_3.fw(167) Version 1.3.3.0: ID: 298980 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(166), 1\8808_2.fw(166), 1\8808_3.fw(166) Version 1.3.1.0: ID: 289010 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 289890 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8808_1.fw(163), 1\8808_2.fw(164), 1\8808_3.fw(164) Version 1.3.0.0: ID: 277160 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277740 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\8808_1.fw(160), 1\8808_2.fw(160), 1\8808_3.fw(160) Version 1.2.1.0: ID: 268450 Netx and Powerlink error correction -NetX correction of plug off/onf the Powerlinkwire by startup -New hwc entries Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(154),1\8808_2.fw(154), 1\8808_3.fw(154) Version 1.2.0.0: ID: 246445 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FWfiles on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\8808_1.fw(152), 1\8808_2.fw(152), 1\8808_3.fw(152) Version 1.1.0.1: ID: 236005 X20 Bus Controller POWERLINK, 1x IF X20 Bus Controller POWERLINK, 1x IF Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(145), 1\8808_2.fw(148) Version 1.1.0.0: ID: 234115 X20 Bus Controller POWERLINK. 1xIF X20 Bus Controller POWERLINK. 1xIF Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(145), 1\8808_2.fw(36) Version 1.0.8.0: ID: 218495 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(145) Version 1.0.6.0: ID: 210970 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(143) Version 1.0.4.0: ID: 183380 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, newFW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8808_1.fw(141) Version 1.0.3.0: ID: 173360 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanismimplemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8808_1.fw(138) Version 1.0.2.0: ID: 164655 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8808_1.fw(136) Version 1.0.1.0: ID: 160935 Error correction IOs on X20IF1091-1 were not initialized correctly when running EPLV2 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8808_1.fw(135) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.1.0.0 | * | 11.04.2019 | 1 MB | EXE | AS2.6_HW_X20BC1083.exe | |
Popis |
V2.6 HW Upgrade (X20BC1083) Revision information X20BC1083 Version 2.1.0.0: ID: 396390 / Support ID: 400138162 Error in small netX configurations In small netX configurations (smaller than the MTU configured in POWERLINK), it was not possible to transfer the configuration. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 402415 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problemalso occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(300), 1\8808_2.fw(300), 1\8808_3.fw(300) Version 2.0.0.0: ID: 374125 / Support ID: 400123625 X20BC1083: Update error X20IF10E3-1after configuration change If the configuration of a X20IF10E3-1 that isconnected to a X20BC1083 POWERLINK X2XLink bus controller was changed, there were occasionally update problems. The logbook filled with warning 20980 and the bus controller was reseting cyclically. Channel description changed: No Configuration description changed: No Firmware changed: No ID: 385855 / Support ID: 400095196 Streaming-Support for IF-Modules on X20BC1083 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 390265 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(210), 1\8808_2.fw(210), 1\8808_3.fw(210) Version 1.3.6.0: ID: 326250 The upgdate ofthe X2IF1043-1 on the X20BC1083 doesn't work Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(171), 1\8808_2.fw(171), 1\8808_3.fw(171) Version 1.3.5.0: ID: 310775 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 310780 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(168), 1\8808_2.fw(168), 1\8808_3.fw(168) Version 1.3.4.0: ID: 304570 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontrollerrestored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(167), 1\8808_2.fw(167), 1\8808_3.fw(167) Version 1.3.3.0: ID: 298980 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(166), 1\8808_2.fw(166), 1\8808_3.fw(166) Version 1.3.1.0: ID: 289010 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 289890 Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 1\8808_1.fw(163), 1\8808_2.fw(164), 1\8808_3.fw(164) Version 1.3.0.0: ID: 277160 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277740 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\8808_1.fw(160), 1\8808_2.fw(160), 1\8808_3.fw(160) Version 1.2.1.0: ID: 268450 Netx and Powerlink error correction -NetX correction of plug off/onf the Powerlinkwire by startup -New hwc entries Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(154), 1\8808_2.fw(154), 1\8808_3.fw(154) Version 1.2.0.0: ID: 246445 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configuration description changed:Yes Firmware changed: Yes Firmware: 1\8808_1.fw(152), 1\8808_2.fw(152), 1\8808_3.fw(152) Version 1.1.0.1: ID: 236005 X20 BusController POWERLINK, 1x IF X20 Bus Controller POWERLINK, 1x IF Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(145), 1\8808_2.fw(148) Version 1.1.0.0: ID: 234115 X20 Bus Controller POWERLINK. 1xIF X20 Bus Controller POWERLINK. 1xIF Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(145), 1\8808_2.fw(36) Version 1.0.8.0: ID: 218495 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(145) Version 1.0.6.0: ID: 210970 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\8808_1.fw(143) Version 1.0.4.0: ID: 183380 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points inHWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8808_1.fw(141) Version 1.0.3.0: ID: 173360 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reducedfrom 180ns to 20ns) (A&P 167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A<(>&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8808_1.fw(138) Version 1.0.2.0: ID: 164655 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8808_1.fw(136) Version 1.0.1.0: ID: 160935 Error correction IOs on X20IF1091-1 were not initialized correctly when running EPLV2 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\8808_1.fw(135) |