DWL@DWL10000437373
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.7.0.0 | * | 23/07/2021 | 3 MB | EXE | AS4_HW_X20RT8202.exe | |
Description |
V4.1 HW Upgrade (X20RT8202) Revision information X20RT8202 Version 1.7.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.6.1.0: ID: 689440 Limitation of the cycle time Channel description changed: No Configuration description changed: No Firmware changed: No ID: 689475 Module documentation revised Data sheet V 1.15 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(430), 1\58715_3.fw(430), 1\58715_4.fw(430) Version 1.6.0.0: ID: 650590 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58715_2.fw(430), 1\58715_3.fw(430), 1\58715_4.fw(430) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: 623540 Bootup time significantly increases with upgrade V1.3.0.0 of X20RT8202 Bootup time has been improved Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.3.1.0: ID:601835 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 601840 Correction HWX-File Parameter description corrected Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.3.0.0: ID: 594490 Support new hw variante 4 with fw v420 Solving bootup problems Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 594900 Added configuration "blackout mode" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 600650 Module documentation revised Data sheet V 1.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.2.0.0: ID: 590145 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 591735 Module documentation revised Data sheet V 1.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420) Version 1.1.1.0: ID: 530775 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(320), 1\58715_3.fw(320) Version 1.1.0.0: ID: 426130 Support X20RT8202 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(240), 1\58715_3.fw(240) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.6.1.0 | * | 10/06/2020 | 3 MB | EXE | AS4_HW_X20RT8202.exe | |
Description |
V4.1 HW Upgrade (X20RT8202) Revision information X20RT8202 Version 1.6.1.0: ID: 689440 Limitation of the cycle time Channel description changed: No Configuration description changed: No Firmware changed: No ID: 689475 Module documentation revised Data sheet V 1.15 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(430), 1\58715_3.fw(430), 1\58715_4.fw(430) Version 1.6.0.0: ID: 650590 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58715_2.fw(430), 1\58715_3.fw(430), 1\58715_4.fw(430) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: 623540 Bootup time significantly increases withupgrade V1.3.0.0 of X20RT8202 Bootup time has been improved Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.3.1.0: ID: 601835 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 601840 Correction HWX-File Parameter description corrected Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.3.0.0: ID: 594490 Support new hwvariante 4 with fw v420 Solving bootup problems Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 594900 Added configuration "blackout mode" Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 600650 Module documentation revised Data sheet V 1.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.2.0.0: ID: 590145 Correction of the functionality of the timestamp outputs Behavourof the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591735 Module documentation revised Data sheet V 1.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420) Version 1.1.1.0: ID: 530775 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(320), 1\58715_3.fw(320) Version 1.1.0.0: ID: 426130 Support X20RT8202 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(240), 1\58715_3.fw(240) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.6.0.0 | * | 16/01/2020 | 3 MB | EXE | AS4_HW_X20RT8202.exe | |
Description |
V4.1 HW Upgrade (X20RT8202) Revision information X20RT8202 Version 1.6.0.0: ID: 650590 Additional status bit for rtiABRPos reference impulse loss An additional status bit was introduced, that detects the loss of the reference impulse signals. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\58715_2.fw(430), 1\58715_3.fw(430), 1\58715_4.fw(430) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: 623540 Bootup time significantly increases with upgrade V1.3.0.0 of X20RT8202 Bootup time has been improved Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.3.1.0: ID: 601835 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 601840 Correction HWX-File Parameterdescription corrected Channel description changed: No Configurationdescription changed: Yes Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.3.0.0: ID: 594490 Support new hw variante 4 with fw v420 Solving bootup problems Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 594900 Added configuration "blackout mode" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 600650 Moduledocumentation revised Data sheet V 1.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.2.0.0: ID: 590145 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591735 Module documentation revised Data sheet V 1.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420) Version 1.1.1.0: ID: 530775 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(320), 1\58715_3.fw(320) Version 1.1.0.0: ID: 426130 Support X20RT8202 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(240), 1\58715_3.fw(240) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.5.0.0 | * | 25/10/2019 | 3 MB | EXE | AS4_HW_X20RT8202.exe | |
Description |
V4.1 HW Upgrade (X20RT8202) Revision information X20RT8202 Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.0.0: ID: 623540 Bootup time significantly increases with upgrade V1.3.0.0 of X20RT8202 Bootup time has been improved Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.3.1.0: ID: 601835 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 601840 Correction HWX-File Parameter description corrected Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.3.0.0: ID: 594490 Support new hw variante 4 with fw v420 Solving bootup problems Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 594900 Added configuration "blackout mode" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 600650 Module documentation revised Data sheet V 1.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.2.0.0: ID: 590145 Correction of the functionality of thetimestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591735 Module documentation revised Data sheet V 1.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420) Version 1.1.1.0: ID: 530775 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(320), 1\58715_3.fw(320) Version 1.1.0.0: ID: 426130 Support X20RT8202 Supportfor Automation Studio Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\58715_2.fw(240), 1\58715_3.fw(240) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.4.0.0 | * | 18/12/2018 | 3 MB | EXE | AS4_HW_X20RT8202.exe | |
Description |
V4.1 HW Upgrade (X20RT8202) Revision information X20RT8202 Version 1.4.0.0: ID: 623540 Bootup time significantly increases withupgrade V1.3.0.0 of X20RT8202 Bootup time has been improved Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.3.1.0: ID: 601835 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 601840 Correction HWX-File Parameter description corrected Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.3.0.0: ID: 594490 Support new hwvariante 4 with fw v420 Solving bootup problems Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 594900 Added configuration "blackout mode" Channeldescription changed: No Configuration description changed: Yes Firmware changed: No ID: 600650 Module documentation revised Data sheet V 1.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.2.0.0: ID: 590145 Correction of the functionality of the timestamp outputs Behavourof the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591735 Module documentation revised Data sheet V 1.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420) Version 1.1.1.0: ID: 530775 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(320), 1\58715_3.fw(320) Version 1.1.0.0: ID: 426130 Support X20RT8202 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(240), 1\58715_3.fw(240) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.3.1.0 | * | 10/08/2018 | 3 MB | EXE | AS4_HW_X20RT8202.exe | |
Description |
V4.1 HW Upgrade (X20RT8202) Revision information X20RT8202 Version 1.3.1.0: ID: 601835 Correction HWX-File Parameter specification corrected Channel description changed: No Configuration description changed: No Firmware changed: No ID: 601840 Correction HWX-File Parameter description corrected Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.3.0.0: ID: 594490 Support new hw variante 4 with fw v420 Solving bootup problems Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 594900 Added configuration "blackout mode" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 600650 Module documentation revised Data sheet V 1.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.2.0.0: ID: 590145 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591735 Module documentation revised Data sheet V 1.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420) Version 1.1.1.0: ID: 530775 Module documentation revised Data sheet V 1.10 Channel description changed: No Configurationdescription changed: No Firmware changed: No Firmware: 1\58715_2.fw(320), 1\58715_3.fw(320) Version 1.1.0.0: ID: 426130 Support X20RT8202 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(240), 1\58715_3.fw(240) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.3.0.0 | * | 28/06/2018 | 3 MB | EXE | AS4_HW_X20RT8202.exe | |
Description |
V4.1 HW Upgrade (X20RT8202) Revision information X20RT8202 Version 1.3.0.0: ID: 594490 Support new hw variante 4 with fw v420 Solving bootup problems Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 594900 Added configuration "blackout mode" Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 600650 Module documentation revised Data sheet V 1.13 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420), 1\58715_4.fw(420) Version 1.2.0.0: ID: 590145 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591735 Module documentation revised Data sheet V 1.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420) Version 1.1.1.0: ID: 530775 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(320),1\58715_3.fw(320) Version 1.1.0.0: ID: 426130 Support X20RT8202 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(240), 1\58715_3.fw(240) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.2.0.0 | * | 24/04/2018 | 2 MB | EXE | AS4_HW_X20RT8202.exe | |
Description |
V4.1 HW Upgrade (X20RT8202) Revision information X20RT8202 Version 1.2.0.0: ID: 590145 Correction of the functionality of the timestamp outputs Behavour of the timestamp Bit0 flags of CntTs and LatchTs outputs corrected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 591735 Module documentation revised Data sheet V 1.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(420), 1\58715_3.fw(420) Version 1.1.1.0: ID: 530775 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(320), 1\58715_3.fw(320) Version 1.1.0.0: ID: 426130 Support X20RT8202 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(240), 1\58715_3.fw(240) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.1.1.0 | * | 02/05/2017 | 2 MB | EXE | AS4_HW_X20RT8202.exe | |
Description |
V4.1 HW Upgrade (X20RT8202) Revision information X20RT8202 Version 1.1.1.0: ID: 530775 Module documentation revised Data sheet V 1.10 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(320), 1\58715_3.fw(320) Version 1.1.0.0: ID: 426130 Support X20RT8202 Support for Automation Studio Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\58715_2.fw(240), 1\58715_3.fw(240) |