DWL@DWL10000462320
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
1.8.0.0 | * | 06/06/2023 | 14 Mo | EXE | AS4_HW_X20CM4810.exe | |
Description |
V4.0 HW Upgrade (X20CM4810) Revision information X20CM4810 Version 1.8.0.0: ID: 766230 Support for hardware variant 2 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(101), 1\51449_2.fw(103) Version 1.7.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.6.1.0: ID: 674690 HWX-file correction Indication error of the configuration at AS.4.2 is corrected Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\51449_1.fw(101) Version 1.6.0.0: ID: 596760 Extension for Fieldbus Designer Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 647125 Firmware extension supporting X20cCM4810 Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\51449_1.fw(101) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.4.0: ID: 588375 Module documentation revised Data sheet V2.17 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.3.0: ID: 546540 Autogain Parameter limitation canceled Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553085 / Support ID: 400228582 Fixed problem in the configuration settings Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 554210 Module documentation revised Data sheet V2.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.2.1: ID: 550890 Module documentation revised Data sheet V2.11 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553085 / Support ID: 400228582 Fixed problem in the configuration settings Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.3: ID: 514140 Fixed bug in hwx file Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.1: ID: 507445 Module documentation revised Data sheet V2.01 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.0: ID: 507445 Module documentation revised Data sheet V2.01 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.0.0: ID: 479050 / Support ID: 400173497 AsIOVib: new FUB "vbioCtrlCM4810Ex1" Bufferupload can be caneled by the user. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(7) Version 1.3.1.1: ID: 424945 Documentation revised Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(6) Version 1.3.0.0: ID: 376140 The number of samples for the parameter calculation in the AnalogInput can now be changed cyclically if needed. Channel description changed: Yes Configuration description changed:Yes Firmware changed: Yes Firmware: 1\51449_1.fw(5) Version 1.2.0.1: ID: 341170 AR verions in AS help updatet Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(4) Version 1.1.2.1: ID: 318860 BufferLockValid01 comes a measurement cycle too late Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 318865 Improved filter characteristics to reduce the noise level Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(3) Version 1.1.1.0: ID: 307990 Support for the moduleX20CM4810 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No ID: 309665 Improved support of X20CM4810 in Automation Studio Channel description changed: Yes Configuration description changed: No Firmware changed: No ID:310445 Fieldbusdesigner support added. Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(1) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.7.0.0 | * | 23/07/2021 | 13 Mo | EXE | AS4_HW_X20CM4810.exe | |
Description |
V4.0 HW Upgrade (X20CM4810) Revision information X20CM4810 Version 1.7.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.6.1.0: ID: 674690 HWX-file correction Indication error of the configuration at AS.4.2 is corrected Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\51449_1.fw(101) Version 1.6.0.0: ID: 596760 Extension for Fieldbus Designer Channeldescription changed: Yes Configuration description changed: Yes Firmware changed: No ID: 647125 Firmware extension supporting X20cCM4810 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(101) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.4.0: ID: 588375 Module documentation revised Data sheet V2.17 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.3.0: ID: 546540 Autogain Parameter limitation canceled Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553085 / Support ID: 400228582 Fixed problem in the configuration settings Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 554210 Module documentation revised Data sheet V2.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.2.1: ID: 550890 Module documentation revised Data sheet V2.11 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553085 / Support ID: 400228582 Fixed problem in the configuration settings Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.3: ID: 514140 Fixed bug in hwx file Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.1: ID: 507445 Module documentation revised Data sheet V2.01 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.0: ID: 507445 Module documentation revised Data sheet V2.01 Channel descriptionchanged: No Configuration description changed: No Firmware changed:No Firmware: 1\51449_1.fw(7) Version 1.4.0.0: ID: 479050/ Support ID: 400173497 AsIOVib: new FUB "vbioCtrlCM4810Ex1" Bufferupload can be caneled by the user. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\51449_1.fw(7) Version 1.3.1.1: ID: 424945 Documentation revised Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(6) Version 1.3.0.0: ID: 376140 The number of samples for the parameter calculation in the AnalogInput can now be changed cyclically if needed. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\51449_1.fw(5) Version 1.2.0.1: ID: 341170 AR verions in AS help updatet Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(4) Version 1.1.2.1: ID: 318860 BufferLockValid01 comes a measurement cycle too late Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 318865 Improved filter characteristics to reduce the noise level Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(3) Version 1.1.1.0: ID: 307990 Support for the module X20CM4810 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 309665 Improved support ofX20CM4810 in Automation Studio Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 310445 Fieldbusdesigner support added. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(1) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.6.1.0 | * | 17/02/2020 | 13 Mo | EXE | AS4_HW_X20CM4810.exe | |
Description |
V4.0 HW Upgrade (X20CM4810) Revision information X20CM4810 Version 1.6.1.0: ID: 674690 HWX-file correction Indication error of the configuration at AS.4.2 is corrected Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\51449_1.fw(101) Version 1.6.0.0: ID: 596760 Extension for Fieldbus Designer Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 647125 Firmware extension supporting X20cCM4810 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(101) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.4.0: ID: 588375 Module documentation revised Data sheet V2.17 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.3.0: ID: 546540 Autogain Parameter limitation canceled Channel description changed: No Configuration description changed:No Firmware changed: No ID: 553085 / Support ID: 400228582 Fixed problem in the configuration settings Channel description changed:No Configuration description changed: Yes Firmware changed: No ID: 554210 Module documentation revised Data sheet V2.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.2.1: ID: 550890 Module documentation revised Data sheet V2.11 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553085 / Support ID: 400228582 Fixed problem in the configuration settings Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.3: ID: 514140 Fixed bug in hwx file Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.1: ID: 507445 Module documentation revised Data sheet V2.01 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.0: ID: 507445 Module documentation revised Data sheet V2.01 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.0.0: ID: 479050 / Support ID: 400173497 AsIOVib: new FUB "vbioCtrlCM4810Ex1" Bufferupload can be caneled by the user. Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\51449_1.fw(7) Version 1.3.1.1: ID: 424945 Documentation revised Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(6) Version 1.3.0.0: ID: 376140 The number of samples for the parameter calculation in the AnalogInput can now be changed cyclically if needed. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\51449_1.fw(5) Version 1.2.0.1: ID: 341170 AR verions in AS help updatet Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(4) Version 1.1.2.1: ID: 318860 BufferLockValid01 comes a measurement cycle too late Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 318865 Improved filter characteristics to reduce the noise level Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(3) Version 1.1.1.0: ID: 307990 Support for the module X20CM4810 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 309665 Improved support of X20CM4810 in Automation Studio Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 310445 Fieldbusdesigner support added. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(1) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.6.0.0 | * | 17/12/2019 | 13 Mo | EXE | AS4_HW_X20CM4810.exe | |
Description |
V4.0 HW Upgrade (X20CM4810) Revision information X20CM4810 Version 1.6.0.0: ID: 596760 Extension for Fieldbus Designer Channel description changed: Yes Configuration description changed: Yes Firmware changed: No ID: 647125 Firmware extension supporting X20cCM4810 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(101) Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.4.0: ID: 588375 Module documentation revised Data sheet V2.17 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.3.0: ID: 546540 Autogain Parameter limitation canceled Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553085 / Support ID: 400228582 Fixed problem in the configuration settings Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 554210 Module documentationrevised Data sheet V2.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.2.1: ID: 550890 Module documentation revised Data sheet V2.11 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553085 / Support ID: 400228582 Fixed problem in the configuration settings Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.3: ID: 514140 Fixed bug in hwx file Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.1: ID: 507445 Module documentation revised Data sheet V2.01 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.0: ID: 507445 Module documentation revised Data sheet V2.01 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.0.0: ID: 479050 / Support ID: 400173497 AsIOVib: new FUB "vbioCtrlCM4810Ex1" Bufferupload can be caneled by the user. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(7) Version 1.3.1.1: ID: 424945 Documentation revised Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(6) Version 1.3.0.0: ID: 376140 The number of samples for the parameter calculation in the AnalogInput can now be changed cyclically if needed. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\51449_1.fw(5) Version 1.2.0.1: ID: 341170 AR verions in AS help updatet Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\51449_1.fw(4) Version 1.1.2.1: ID: 318860 BufferLockValid01 comes a measurement cycle too late Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 318865 Improved filter characteristics toreduce the noise level Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(3) Version 1.1.1.0: ID: 307990 Support for the module X20CM4810 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 309665 Improved support of X20CM4810 in Automation Studio Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 310445 Fieldbusdesigner support added. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(1) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.5.0.0 | * | 25/10/2019 | 13 Mo | EXE | AS4_HW_X20CM4810.exe | |
Description |
V4.0 HW Upgrade (X20CM4810) Revision information X20CM4810 Version 1.5.0.0: ID: Adaptations for Automation Studio 4.8 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 1.4.4.0: ID: 588375 Module documentation revised Data sheet V2.17 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.3.0: ID: 546540 Autogain Parameter limitation canceled Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553085 / Support ID: 400228582 Fixed problem in the configuration settings Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 554210 Module documentation revised Data sheet V2.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.2.1: ID: 550890 Module documentation revised Data sheet V2.11 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553085 /Support ID: 400228582 Fixed problem in the configuration settings Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.3: ID: 514140 Fixed bug in hwx file Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.1: ID: 507445 Module documentation revised Data sheet V2.01 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.0: ID: 507445 Module documentation revised Data sheet V2.01 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.0.0: ID: 479050 / Support ID: 400173497 AsIOVib: new FUB "vbioCtrlCM4810Ex1" Bufferupload can be caneled by the user. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(7) Version 1.3.1.1: ID: 424945 Documentationrevised Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(6) Version 1.3.0.0: ID: 376140 The number of samples for the parametercalculation in the AnalogInput can now be changed cyclically if needed. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\51449_1.fw(5) Version 1.2.0.1: ID: 341170 AR verions in AS help updatet Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(4) Version 1.1.2.1: ID: 318860 BufferLockValid01 comes a measurement cycle too late Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 318865 Improved filter characteristics to reduce the noise level Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(3) Version 1.1.1.0: ID: 307990 Support for the module X20CM4810 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 309665 Improved support of X20CM4810 in Automation Studio Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 310445 Fieldbusdesigner support added. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(1) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.4.4.0 | * | 20/04/2018 | 13 Mo | EXE | AS4_HW_X20CM4810.exe | |
Description |
V4.0 HW Upgrade (X20CM4810) Revision information X20CM4810 Version 1.4.4.0: ID: 588375 Module documentation revised Data sheet V2.17 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.3.0: ID: 546540 Autogain Parameter limitation canceled Channel description changed: No Configuration description changed:No Firmware changed: No ID: 553085 / Support ID: 400228582 Fixed problem in the configuration settings Channel description changed:No Configuration description changed: Yes Firmware changed: No ID: 554210 Module documentation revised Data sheet V2.12 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.2.1: ID: 550890 Module documentation revised Data sheet V2.11 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 553085 / Support ID: 400228582 Fixed problem in the configuration settings Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.3: ID: 514140 Fixed bug in hwx file Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.1: ID: 507445 Module documentation revised Data sheet V2.01 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.1.0: ID: 507445 Module documentation revised Data sheet V2.01 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(7) Version 1.4.0.0: ID: 479050 / Support ID: 400173497 AsIOVib: new FUB "vbioCtrlCM4810Ex1" Bufferupload can be caneled by the user. Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\51449_1.fw(7) Version 1.3.1.1: ID: 424945 Documentation revised Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(6) Version 1.3.0.0: ID: 376140 The number of samples for the parameter calculation in the AnalogInput can now be changed cyclically if needed. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\51449_1.fw(5) Version 1.2.0.1: ID: 341170 AR verions in AS help updatet Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(4) Version 1.1.2.1: ID: 318860 BufferLockValid01 comes a measurement cycle too late Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 318865 Improved filter characteristics to reduce the noise level Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(3) Version 1.1.1.0: ID: 307990 Support for the module X20CM4810 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 309665 Improved support of X20CM4810 in Automation Studio Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 310445 Fieldbusdesigner support added. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(1) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.4.0.0 | * | 20/12/2016 | 4 Mo | EXE | AS4_HW_X20CM4810.exe | |
Description |
V4.0 HW Upgrade (X20CM4810) Revision information X20CM4810 Version 1.4.0.0: ID: 479050 / Support ID: 400173497 AsIOVib: newFUB"vbioCtrlCM4810Ex1" Bufferupload can be caneled by the user. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(7) Version 1.3.1.1: ID: 424945 Documentation revised Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(6) Version 1.3.0.0: ID: 376140 The number of samples for the parameter calculation in the AnalogInput can now be changed cyclically if needed. Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\51449_1.fw(5) Version 1.2.0.1: ID: 341170 AR verions in AS help updatet Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(4) Version 1.1.2.1: ID: 318860 BufferLockValid01 comes a measurement cycle too late Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 318865 Improved filter characteristics to reduce the noise level Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\51449_1.fw(3) Version 1.1.1.0: ID: 307990 Support for the module X20CM4810 Channel description changed: No Configuration description changed: No Firmware changed: No ID:309665 Improved support of X20CM4810 in Automation Studio Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 310445 Fieldbusdesigner support added. Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\51449_1.fw(1) |