Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
2.4.0.0 | * | 08/04/2024 | 4 Mo | EXE | AS4_HW_X20CM0985-1.exe | |
Description |
V4.0 HW Upgrade (X20CM0985-1) Revision information X20CM0985-1 Version 2.4.0.0: ID: 769515 / Support ID: 400402294 Continuous RMS measurement after phase loss Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(200) Version 2.3.1.0: ID: 721790 Value area extension for unbalanced load constant current asymmetry (K2). A range of values from 8 to 35 (0.08 to 0.35) is possible Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(111) Version 2.3.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 2.2.0.0: ID: 630775 / Support ID: 400268833, 400284558 Configuration parameter implemented to deactivate the evaluation of the current inputs if the generator voltages are missing This prevents a noise at the current inputs being evaluated and leading to incorrect measured values, e.g. whenthe generator is not connected Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 655725 / Support ID: 400294065 Frequency measurement improved Plausibility check is more robust against saddle-shaped signals in the areaof the zero crossing. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 670145 / Support ID: 400305545 Problem at startup of the X2X fixed X2X telegrams are no longer forwarded too early to subsequent X2X slaves during the startup phase. Thus, it is no longer possible for a mismatched FW to be loaded to the subsequent X2X slave. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 680810 / Support ID: 400316271 Uneven load monitoring adapted for high unbalanced load currents With unbalanced load currents above 4 times the nominal current, a fault isno longer immediately output Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688170 additional continuous current tripping characteristics Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 690325 Module documentation revised Data sheet V 1.45 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_2.fw(110) Version 2.1.0.0: ID: 503770 Units adapted for display in AS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 674135 Adaptations for AutomationStudio 4.8 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_2.fw(107) Version 2.0.0.0: ID: 645125 Module documentation revised Data sheet V1.41 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 653650 If the"Over- and undervoltages check method" is configured to "Line voltages" or "Phase and line voltages", the "Over voltage of one phase" configurationis incorrectly used for generator monitoring for "Over voltage 2 of one phase". Before using this upgrade, it is therefore necessary to check the correct configuration of "Over voltage 2 of one phase" for generator monitoring. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(107) Version 1.9.0.0: ID: 608520 X5- X3 synchronization not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 611470 / Support ID: 400253780 Increased threshold for plausibility check of current inputs in the 1 A measuring range and thusless sensitive to interference Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(106) Version 1.8.1.0: ID: 563885 Module documentation revised Data sheet V1.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.8.0.0: ID: 545065 Increase of the configurable limits of ConfigOutput11 and ConfigOutput12 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.7.1.0: ID: 480835 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.7.0.0: ID: 464525 / Support ID: 400176549 The unbalance current was displayed incorrectly for current left rotating direction Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 474130 Module documentation revised Data sheet V1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.6.1.0: ID: 458530 Module documentation revised Datasheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.1: ID: 397120 Renewed documentation in English Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.0: ID: 378440 Configuration of the direction of rotationpossible Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 378455 Extension of the monitoring functions in the generator net and mains Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 378460 Accelerate the release of the synchronization Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.5.0.0: ID: 351350 Extension: Power measurement on 1. harmonic Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\46952_1.fw(101), 1\46952_2.fw(101) Version 1.4.2.0: ID: 306890 / SupportID: 400082323 Bootup time of X20 system too long if module is configuredbut not plugged. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) Version 1.4.1.0: ID: 293590 Extension to make all configuration registers readable Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.3.1.0 | * | 06/09/2021 | 3 Mo | EXE | AS4_HW_X20CM0985-1.exe | |
Description |
V4.0 HW Upgrade (X20CM0985-1) Revision information X20CM0985-1 Version 2.3.1.0: ID: 721790 Value area extension for unbalanced load constant current asymmetry (K2). A range of values ##from 8 to 35 (0.08 to 0.35) is possible Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(111) Version 2.3.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 2.2.0.0: ID: 630775 / Support ID: 400268833, 400284558 Configuration parameter implemented to deactivate the evaluation of the current inputs if the generator voltages are missing This prevents a noise at the current inputs being evaluated and leading to incorrect measured values, e.g. when the generator is notconnected Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 655725 / Support ID: 400294065 Frequency measurement improved Plausibility check is more robust against saddle-shaped signals in the areaof the zero crossing. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 670145 / Support ID: 400305545 Problem at startup of the X2X fixed X2X telegrams are no longer forwarded too early to subsequent X2X slaves during the startup phase. Thus, it is no longer possible for a mismatched FW to be loaded to the subsequent X2X slave. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 680810 / Support ID: 400316271 Uneven load monitoring adapted for high unbalanced load currents With unbalanced load currents above 4 times the nominal current, a fault isno longer immediately output Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688170 additional continuous current tripping characteristics Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 690325 Module documentation revised Data sheet V 1.45 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_2.fw(110) Version 2.1.0.0: ID: 503770 Units adapted for display in AS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 674135 Adaptations for Automation Studio 4.8 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_2.fw(107) Version 2.0.0.0: ID: 645125 Module documentation revised Data sheet V1.41 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 653650 If the "Over- and undervoltages check method" is configured to "Line voltages" or "Phase and line voltages", the "Over voltage of one phase" configuration is incorrectly used for generator monitoring for "Over voltage 2 of one phase". Before using this upgrade, it is therefore necessary to check the correct configuration of "Over voltage 2 of one phase" for generator monitoring. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(107) Version 1.9.0.0: ID: 608520 X5- X3 synchronization not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 611470 / Support ID: 400253780 Increased threshold for plausibility check of current inputs in the 1 A measuring range and thus less sensitive to interference Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\46952_2.fw(106) Version 1.8.1.0: ID: 563885 Module documentation revised Data sheet V1.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(105),1\46952_2.fw(105) Version 1.8.0.0: ID: 545065 Increase of the configurable limits of ConfigOutput11 and ConfigOutput12 Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.7.1.0: ID: 480835 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.7.0.0: ID: 464525 / Support ID: 400176549 The unbalance current was displayed incorrectly for current left rotating direction Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 474130 Module documentation revised Datasheet V1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.6.1.0: ID: 458530 Module documentation revised Datasheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.1: ID: 397120 Renewed documentation in English Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.0: ID: 378440 Configuration of the direction of rotation possible Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 378455 Extension of the monitoring functions in the generator net and mains Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID:378460 Accelerate the release of the synchronization Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.5.0.0: ID: 351350 Extension: Power measurement on 1. harmonic Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\46952_1.fw(101), 1\46952_2.fw(101) Version 1.4.2.0: ID: 306890 / Support ID: 400082323 Bootup time of X20 system too long if module is configured but not plugged. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) Version 1.4.1.0: ID: 293590 Extension to make all configuration registers readable Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.3.0.0 | * | 23/07/2021 | 3 Mo | EXE | AS4_HW_X20CM0985-1.exe | |
Description |
V4.0 HW Upgrade (X20CM0985-1) Revision information X20CM0985-1 Version 2.3.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 2.2.0.0: ID: 630775 / Support ID: 400268833, 400284558 Configuration parameter implemented to deactivate the evaluation of the current inputs if the generator voltages are missing This prevents a noise at the current inputs being evaluated and leading to incorrect measured values, e.g. when the generator is not connected Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 655725 / Support ID: 400294065 Frequency measurement improved Plausibility check is more robust against saddle-shaped signals in the areaof the zero crossing. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 670145 / Support ID: 400305545 Problem at startup of theX2X fixed X2X telegrams are no longer forwarded too early to subsequent X2X slaves during the startup phase. Thus, it is no longer possible for a mismatched FW to be loaded to the subsequent X2X slave. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 680810 / Support ID: 400316271 Uneven load monitoring adapted for high unbalanced load currents With unbalanced load currents above 4 times the nominal current, a fault isno longer immediately output Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688170 additional continuous current tripping characteristics Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 690325 Module documentation revised Data sheet V 1.45 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_2.fw(110) Version 2.1.0.0: ID: 503770 Units adapted for display in AS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 674135 Adaptations for Automation Studio 4.8 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_2.fw(107) Version 2.0.0.0: ID: 645125 Module documentation revised Data sheet V1.41 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 653650 If the "Over- and undervoltages check method" is configured to "Line voltages" or "Phase and line voltages", the "Over voltage of one phase" configuration is incorrectly used for generator monitoringfor "Over voltage 2 of one phase". Before using this upgrade, it is therefore necessary to check the correct configuration of "Over voltage 2 of one phase" for generator monitoring. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(107) Version 1.9.0.0: ID: 608520 X5- X3 synchronization not working Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 611470 / Support ID: 400253780 Increased threshold for plausibility check of current inputs in the 1 A measuring range and thus less sensitive to interference Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(106) Version 1.8.1.0: ID: 563885 Module documentation revised Data sheet V1.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.8.0.0: ID: 545065 Increase of the configurable limits of ConfigOutput11 and ConfigOutput12 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.7.1.0: ID: 480835 Enhancement online-help Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.7.0.0: ID: 464525 / Support ID: 400176549 The unbalance current was displayed incorrectly for current left rotating direction Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 474130 Module documentation revised Data sheet V1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.6.1.0: ID: 458530 Module documentation revised Datasheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.1: ID: 397120 Reneweddocumentation in English Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.0: ID: 378440 Configuration of the direction of rotation possible Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 378455 Extension of the monitoring functions in the generator net and mains Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 378460 Accelerate the release of the synchronization Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.5.0.0: ID: 351350 Extension: Power measurement on 1. harmonic Channel description changed: Yes Configuration description changed: Yes Firmwarechanged: Yes Firmware: 1\46952_1.fw(101), 1\46952_2.fw(101) Version 1.4.2.0: ID: 306890 / Support ID: 400082323 Bootup time of X20 system too long if module is configured but not plugged. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) Version 1.4.1.0: ID: 293590 Extension to make all configuration registersreadable Channel description changed: Yes Configuration descriptionchanged: No Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.2.0.0 | * | 28/05/2020 | 3 Mo | EXE | AS4_HW_X20CM0985-1.exe | |
Description |
V4.0 HW Upgrade (X20CM0985-1) Revision information X20CM0985-1 Version 2.2.0.0: ID: 630775 / Support ID: 400268833, 400284558 Configuration parameter implemented to deactivate the evaluation of the currentinputs if the generator voltages are missing This prevents a noise at the current inputs being evaluated and leading to incorrect measured values, e.g. when the generator is not connected Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 655725 / Support ID: 400294065 Frequency measurement improved Plausibility check is more robust against saddle-shaped signals in the areaof the zero crossing. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 670145 / Support ID: 400305545 Problem at startup of the X2X fixed X2X telegrams are no longer forwarded too early to subsequent X2X slaves during the startup phase. Thus, it is no longer possible for a mismatched FW to be loaded to the subsequent X2X slave. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 680810 / Support ID: 400316271 Uneven load monitoring adapted for high unbalanced load currents With unbalanced load currents above 4 times the nominal current, a fault isno longer immediately output Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 688170 additional continuous current tripping characteristics Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 690325 Module documentation revised Data sheet V 1.45 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_2.fw(110) Version 2.1.0.0: ID: 503770 Units adapted for display inAS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 674135 Adaptations for Automation Studio 4.8 Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_2.fw(107) Version 2.0.0.0: ID: 645125 Module documentation revised Data sheet V1.41 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 653650 If the "Over- and undervoltages check method" is configured to "Line voltages"or "Phase and line voltages", the "Over voltage of one phase" configurationis incorrectly used for generator monitoring for "Over voltage 2 of one phase". Before using this upgrade, it is therefore necessary to check the correct configuration of "Over voltage 2 of one phase" for generator monitoring. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(107) Version 1.9.0.0: ID: 608520 X5- X3 synchronization not working Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 611470 / Support ID: 400253780 Increased threshold for plausibility check of current inputs in the 1 A measuring range and thus less sensitive to interference Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(106) Version 1.8.1.0: ID: 563885 Module documentation revised Data sheet V1.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.8.0.0: ID: 545065 Increase of the configurable limits of ConfigOutput11 and ConfigOutput12 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.7.1.0: ID: 480835 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.7.0.0: ID: 464525 / Support ID: 400176549 The unbalance current was displayed incorrectly for current left rotating direction Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 474130 Module documentation revised Data sheet V1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.6.1.0: ID:458530 Module documentation revised Datasheet V1.20 Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.1: ID: 397120 Renewed documentation in English Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.0: ID: 378440 Configuration of the direction of rotation possible Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 378455 Extension of the monitoring functions in the generator net and mains Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 378460 Accelerate the release of the synchronization Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.5.0.0: ID: 351350 Extension: Power measurement on 1. harmonic Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\46952_1.fw(101), 1\46952_2.fw(101) Version 1.4.2.0: ID: 306890 / Support ID: 400082323 Bootup time of X20 system too long if module is configured but not plugged. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) Version 1.4.1.0: ID: 293590 Extension to make all configuration registers readable Channel description changed: Yes Configuration description changed: No Firmware changed:No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.1.0.0 | * | 08/01/2020 | 3 Mo | EXE | AS4_HW_X20CM0985-1.exe | |
Description |
V4.0 HW Upgrade (X20CM0985-1) Revision information X20CM0985-1 Version 2.1.0.0: ID: 503770 Units adapted for display in AS Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 674135 Adaptations for Automation Studio 4.8 Channel description changed: Yes Configuration descriptionchanged: Yes Firmware changed: No Firmware: 1\46952_2.fw(107) Version 2.0.0.0: ID: 645125 Module documentation revised Data sheet V1.41 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 653650 If the "Over- and undervoltages check method" is configured to "Line voltages" or "Phase and line voltages", the "Over voltage of one phase" configuration is incorrectly used for generator monitoring for "Over voltage 2 of one phase". Before using this upgrade, it is therefore necessary to check the correct configuration of "Over voltage 2 of one phase" for generator monitoring. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(107) Version 1.9.0.0: ID: 608520 X5- X3 synchronization not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 611470 / Support ID: 400253780 Increased threshold for plausibility check of current inputs in the 1 A measuring range and thus less sensitive to interference Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(106) Version 1.8.1.0: ID: 563885 Module documentation revised Data sheet V1.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.8.0.0: ID: 545065 Increase of the configurable limits of ConfigOutput11 and ConfigOutput12 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.7.1.0: ID: 480835 Enhancement online-help Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.7.0.0: ID: 464525 / Support ID: 400176549 The unbalance current was displayed incorrectly for current left rotating direction Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 474130 Module documentation revised Data sheet V1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.6.1.0: ID: 458530 Module documentation revised Datasheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.1: ID: 397120 Renewed documentation in English Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.0: ID: 378440 Configuration of the direction of rotation possible Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 378455 Extension of the monitoring functions in the generator net and mains Channel descriptionchanged: Yes Configuration description changed: Yes Firmware changed: Yes ID: 378460 Accelerate the release of the synchronization Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.5.0.0: ID: 351350 Extension: Power measurement on 1. harmonic Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\46952_1.fw(101), 1\46952_2.fw(101) Version 1.4.2.0: ID: 306890 / Support ID: 400082323 Bootup time of X20 system too long if module is configured but not plugged. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_1.fw(100),1\46952_2.fw(100) Version 1.4.1.0: ID: 293590 Extension to make all configuration registers readable Channel description changed:Yes Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.0.0.0 | * | 17/07/2019 | 3 Mo | EXE | AS4_HW_X20CM0985-1.exe | |
Description |
V4.0 HW Upgrade (X20CM0985-1) Revision information X20CM0985-1 Version 2.0.0.0: ID: 645125 Module documentation revised Data sheet V1.41 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 653650 If the "Over- and undervoltages check method" is configured to "Line voltages" or "Phaseand line voltages", the "Over voltage of one phase" configurationis incorrectly used for generator monitoring for "Over voltage 2 of one phase". Before using this upgrade, it is therefore necessary to check the correct configuration of "Over voltage 2 of one phase" for generator monitoring. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(107) Version 1.9.0.0: ID: 608520 X5- X3 synchronization not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 611470 / Support ID: 400253780 Increased threshold for plausibility check of current inputs in the 1 A measuring range and thus less sensitive to interference Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(106) Version 1.8.1.0: ID: 563885 Module documentation revised Data sheet V1.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.8.0.0: ID: 545065 Increase of the configurable limits of ConfigOutput11 and ConfigOutput12 Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.7.1.0: ID: 480835 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.7.0.0: ID: 464525 / Support ID: 400176549 Theunbalance current was displayed incorrectly for current left rotating direction Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 474130 Module documentation revised Data sheet V1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.6.1.0: ID: 458530 Module documentation revised Datasheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.1: ID: 397120 Renewed documentation in English Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.0: ID: 378440 Configuration of the direction of rotation possible Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 378455 Extension of the monitoring functions in the generator net and mains Channel description changed: Yes Configuration description changed: Yes Firmware changed:Yes ID: 378460 Accelerate the release of the synchronization Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.5.0.0: ID: 351350 Extension: Power measurementon 1. harmonic Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\46952_1.fw(101), 1\46952_2.fw(101) Version 1.4.2.0: ID: 306890 / Support ID:400082323 Bootup time of X20 system too long if module is configured butnot plugged. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) Version 1.4.1.0: ID: 293590 Extension tomake all configuration registers readable Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.9.0.0 | * | 09/11/2018 | 3 Mo | EXE | AS4_HW_X20CM0985-1.exe | |
Description |
V4.0 HW Upgrade (X20CM0985-1) Revision information X20CM0985-1 Version 1.9.0.0: ID: 608520 X5- X3 synchronization not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 611470 / Support ID: 400253780 Increased threshold for plausibility check of current inputs in the 1 A measuring range and thus less sensitive to interference Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_2.fw(106) Version 1.8.1.0: ID: 563885 Module documentation revised Data sheet V1.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.8.0.0: ID: 545065 Increase of the configurable limits of ConfigOutput11 and ConfigOutput12 Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.7.1.0: ID: 480835 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.7.0.0: ID: 464525 / Support ID: 400176549 The unbalance current was displayed incorrectly for current left rotating direction Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 474130 Module documentation revised Data sheet V1.21 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.6.1.0: ID: 458530 Module documentation revised Datasheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.1: ID: 397120 Renewed documentation in English Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.0: ID: 378440 Configuration of the direction of rotation possible Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 378455 Extension of the monitoring functions in the generator net and mains Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 378460 Accelerate the release of the synchronization Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.5.0.0: ID: 351350 Extension: Power measurement on 1. harmonic Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\46952_1.fw(101), 1\46952_2.fw(101) Version 1.4.2.0: ID:306890 / Support ID: 400082323 Bootup time of X20 system too long if module is configured but not plugged. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware:1\46952_1.fw(100), 1\46952_2.fw(100) Version 1.4.1.0: ID: 293590 Extension to make all configuration registers readable Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
1.8.1.0 | * | 04/12/2017 | 3 Mo | EXE | AS4_HW_X20CM0985-1.exe | |
Description |
V4.0 HW Upgrade (X20CM0985-1) Revision information X20CM0985-1 Version 1.8.1.0: ID: 563885 Module documentation revised Data sheet V1.33 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version 1.8.0.0: ID: 545065 Increase of the configurable limits of ConfigOutput11 and ConfigOutput12 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(105), 1\46952_2.fw(105) Version1.7.1.0: ID: 480835 Enhancement online-help Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.7.0.0: ID: 464525 / Support ID: 400176549 The unbalance current was displayed incorrectly for current left rotating direction Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 474130 Module documentation revised Data sheet V1.21 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\46952_1.fw(104), 1\46952_2.fw(104) Version 1.6.1.0: ID: 458530 Module documentation revised Datasheet V1.20 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.1: ID: 397120 Renewed documentation in English Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.6.0.0: ID:378440 Configuration of the direction of rotation possible Channel description changed: No Configuration description changed: Yes Firmware changed: Yes ID: 378455 Extension of the monitoring functions in the generator net and mains Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes ID: 378460 Accelerate the release of the synchronization Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\46952_1.fw(102), 1\46952_2.fw(102) Version 1.5.0.0: ID: 351350 Extension: Power measurement on 1. harmonic Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\46952_1.fw(101), 1\46952_2.fw(101) Version 1.4.2.0: ID: 306890 / Support ID: 400082323 Bootup time of X20 system too long if module is configured but not plugged. Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) Version 1.4.1.0: ID: 293590 Extension to make all configuration registers readable Channel description changed: Yes Configuration description changed: No Firmware changed: No Firmware: 1\46952_1.fw(100), 1\46952_2.fw(100) |