DWL@DWL10000302967
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
---|---|---|---|---|---|---|
2.16.0.0 | * | 01/09/2023 | 2 Mo | EXE | AS4_HW_X20BC8084.exe | |
Description |
V4.0 HW Upgrade (X20BC8084) Revision information X20BC8084 Version 2.16.0.0: ID: 774130 Continuous product improvement Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(436), 1\9844_2.fw(436), 1\9844_3.fw(436), 1\9844_4.fw(436), 1\9844_5.fw(436), 1\9844_6.fw(436), 1\9844_7.fw(436) Version 2.15.0.0: ID: 758770 Optimization of asynchronous register access Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(433), 1\9844_2.fw(433), 1\9844_3.fw(433), 1\9844_4.fw(433), 1\9844_5.fw(433), 1\9844_6.fw(433), 1\9844_7.fw(433) Version 2.14.0.0: ID: 727075 / Support ID: 400352981 New configuration parameter: Redundancy Tx mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 730635 Documentation updated Version 2.41 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 736525 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IPstack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 736560 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 739435 Module documentation revised Data sheet V2.41 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(432), 1\9844_2.fw(432), 1\9844_3.fw(432), 1\9844_4.fw(432), 1\9844_5.fw(432), 1\9844_6.fw(432), 1\9844_7.fw(432) Version 2.12.1.0: ID: 727075 / Support ID: 400352981 New configuration parameter: Redundancy Tx mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 730635 Documentation updated Version 2.40 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(430), 1\9844_2.fw(430), 1\9844_3.fw(430), 1\9844_4.fw(430), 1\9844_5.fw(430), 1\9844_6.fw(430), 1\9844_7.fw(430) Version 2.12.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 2.11.0.0: ID: 664370 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664375 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665750 ModuleOk of IO moduleFALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665835 Accessing non-cyclic registerswith AsIOAcc while ModuleOk = FALSE prevents module from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666195 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(430), 1\9844_2.fw(430), 1\9844_3.fw(430), 1\9844_4.fw(430), 1\9844_5.fw(430), 1\9844_6.fw(430), 1\9844_7.fw(430) Version 2.10.0.0: ID: 647935 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(428), 1\9844_2.fw(428), 1\9844_3.fw(428), 1\9844_4.fw(428), 1\9844_5.fw(428), 1\9844_6.fw(428), 1\9844_7.fw(428) Version 2.9.0.0: ID: 624085 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629010 Ring redundancy: Cannot addressthe CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629075 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629160 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\9844_1.fw(427), 1\9844_2.fw(427), 1\9844_3.fw(427), 1\9844_4.fw(427), 1\9844_5.fw(427), 1\9844_6.fw(427) Version 2.8.0.0: ID: 619145 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabledin rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619180 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(426), 1\9844_2.fw(426), 1\9844_3.fw(426), 1\9844_4.fw(426), 1\9844_5.fw(426), 1\9844_6.fw(426) Version 2.7.0.0: ID: 586760 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424), 1\9844_5.fw(424), 1\9844_6.fw(424) Version 2.6.0.0: ID: 574935 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423) Version 2.5.6.0: ID: 565090 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422) Version 2.5.5.0: ID: 551120 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421) Version 2.5.4.0: ID: 540315 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419) Version 2.5.3.0: ID: 523470 / Support ID: 400205694 safety modules not switching to operationalstate SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417) Version 2.5.2.0: ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long timetakes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(415),1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415) Version 2.5.0.0: ID: 468060 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468065 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468070 / Support ID: 400177243 X2XFW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468530 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413) Version 2.3.0.0: ID: 454760 AS, System Designer support: cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No ID: 460105 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460225 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466675 Module documentation revised Data sheet V 2.32 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411) Version 2.2.1.0: ID: 449590 Error when running X20BC8084 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401) Version 2.2.0.0: ID: 439100 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439205 / Support ID: 400128436 I/O modules behind POWERLINK buscontrollers no longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400) Version 2.1.0.0: ID: 404490 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake betweenAutomation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300) Version 2.0.0.0: ID: 390280 / Support ID: 400129274 UncommonX2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210) Version 1.3.7.0: ID: 376980 With special constructions it couldbe that stations will be lost. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174) Version 1.3.6.0: ID: 326655 Link-Selektor funktion upgraded Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169) Version 1.3.5.0: ID: 310790 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311025 / Support ID: 400051206 Expansion: Link-selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168) Version 1.3.4.0: ID: 305155 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused thesafety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167) Version 1.3.3.0: ID: 298990 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165) Version 1.3.2.0: ID:289020 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 291455 Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164) Version 1.3.0.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277180 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277750 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160) Version 1.2.1.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154) Version 1.2.0.0: ID: 265540 Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved - optimation of Kabelredundancy (Link Selector) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h, 2000h/9 and 20F0h/31 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.9.0: ID: 220450 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) - Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.8.0: ID: 218545 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(145) Version 1.0.4.0: ID: 183390 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(141) Version 1.0.3.0: ID: 173290 First version of the buscontroller with cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(138) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.15.0.0 | * | 13/10/2022 | 2 Mo | EXE | AS4_HW_X20BC8084.exe | |
Description |
V4.0 HW Upgrade (X20BC8084) Revision information X20BC8084 Version 2.15.0.0: ID: 758770 Optimization of asynchronous register access Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(433), 1\9844_2.fw(433), 1\9844_3.fw(433), 1\9844_4.fw(433), 1\9844_5.fw(433), 1\9844_6.fw(433), 1\9844_7.fw(433) Version 2.14.0.0: ID: 727075 / Support ID: 400352981 New configuration parameter: Redundancy Tx mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 730635 Documentation updated Version 2.41 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 736525 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 736560 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 739435 Module documentation revised Data sheet V2.41 Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(432), 1\9844_2.fw(432), 1\9844_3.fw(432), 1\9844_4.fw(432), 1\9844_5.fw(432), 1\9844_6.fw(432), 1\9844_7.fw(432) Version 2.12.1.0: ID: 727075 / Support ID: 400352981 New configuration parameter: Redundancy Tx mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 730635 Documentation updated Version 2.40 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(430), 1\9844_2.fw(430), 1\9844_3.fw(430),1\9844_4.fw(430), 1\9844_5.fw(430), 1\9844_6.fw(430), 1\9844_7.fw(430) Version 2.12.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 2.11.0.0: ID: 664370 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664375 Adaptations for Automation Studio 4.8 Channeldescription changed: No Configuration description changed: No Firmware changed: No ID: 665750 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665835 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666195 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(430), 1\9844_2.fw(430), 1\9844_3.fw(430), 1\9844_4.fw(430), 1\9844_5.fw(430), 1\9844_6.fw(430), 1\9844_7.fw(430) Version 2.10.0.0: ID: 647935 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(428), 1\9844_2.fw(428), 1\9844_3.fw(428), 1\9844_4.fw(428), 1\9844_5.fw(428), 1\9844_6.fw(428), 1\9844_7.fw(428) Version 2.9.0.0: ID: 624085 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629010 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629075 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629160 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(427), 1\9844_2.fw(427), 1\9844_3.fw(427), 1\9844_4.fw(427), 1\9844_5.fw(427), 1\9844_6.fw(427) Version 2.8.0.0: ID: 619145 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619180 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(426), 1\9844_2.fw(426), 1\9844_3.fw(426), 1\9844_4.fw(426), 1\9844_5.fw(426), 1\9844_6.fw(426) Version 2.7.0.0: ID: 586760 / Support ID:400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424), 1\9844_5.fw(424), 1\9844_6.fw(424) Version 2.6.0.0: ID: 574935 Optimization of boot procedure forhardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423) Version 2.5.6.0: ID: 565090 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422) Version 2.5.5.0: ID: 551120 Startup timeoptimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421) Version 2.5.4.0: ID: 540315 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419) Version 2.5.3.0: ID: 523470 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417) Version 2.5.2.0: ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415) Version 2.5.0.0: ID: 468060 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468065 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468070 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468530 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413) Version 2.3.0.0: ID: 454760 AS, System Designer support: cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No ID: 460105 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460225 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466675 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411) Version 2.2.1.0: ID: 449590 Error when running X20BC8084 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401) Version 2.2.0.0: ID: 439100 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439205/ Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400) Version 2.1.0.0: ID: 404490 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power,but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300) Version 2.0.0.0: ID: 390280 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210) Version 1.3.7.0: ID: 376980 With special constructions it could be that stations will be lost. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174) Version 1.3.6.0: ID: 326655 Link-Selektor funktion upgraded Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169) Version 1.3.5.0: ID: 310790 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311025 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168) Version 1.3.4.0: ID: 305155 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167) Version 1.3.3.0: ID: 298990 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165) Version 1.3.2.0: ID: 289020 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 291455 Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164) Version 1.3.0.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277180 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277750 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160) Version 1.2.1.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154) Version 1.2.0.0: ID: 265540 Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved - optimation of Kabelredundancy (Link Selector) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h, 2000h/9 and 20F0h/31 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.9.0: ID: 220450 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) - Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1 Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\9844_2.fw(146) Version 1.0.8.0: ID: 218545 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\9844_1.fw(145) Version 1.0.4.0: ID: 183390 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(141) Version 1.0.3.0: ID: 173290 First version of the buscontroller with cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(138) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.14.0.0 | * | 18/10/2021 | 2 Mo | EXE | AS4_HW_X20BC8084.exe | |
Description |
V4.0 HW Upgrade (X20BC8084) Revision information X20BC8084 Version 2.14.0.0: ID: 727075 / Support ID: 400352981 New configuration parameter: Redundancy Tx mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 730635 Documentation updated Version 2.41 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 736525 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 736560 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 739435 Module documentation revised Data sheet V2.41 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:1\9844_1.fw(432), 1\9844_2.fw(432), 1\9844_3.fw(432), 1\9844_4.fw(432), 1\9844_5.fw(432), 1\9844_6.fw(432), 1\9844_7.fw(432) Version 2.12.1.0: ID: 727075 / Support ID: 400352981 New configuration parameter: Redundancy Tx mode Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 730635 Documentation updated Version 2.40 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(430), 1\9844_2.fw(430), 1\9844_3.fw(430), 1\9844_4.fw(430), 1\9844_5.fw(430), 1\9844_6.fw(430), 1\9844_7.fw(430) Version 2.12.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 2.11.0.0: ID: 664370 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664375 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665750 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665835 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666195 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(430), 1\9844_2.fw(430), 1\9844_3.fw(430), 1\9844_4.fw(430), 1\9844_5.fw(430), 1\9844_6.fw(430), 1\9844_7.fw(430) Version 2.10.0.0: ID: 647935 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(428), 1\9844_2.fw(428), 1\9844_3.fw(428), 1\9844_4.fw(428), 1\9844_5.fw(428), 1\9844_6.fw(428), 1\9844_7.fw(428) Version 2.9.0.0: ID: 624085 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629010 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629075 DNA: BC as head-end station switching huboff again Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 629160 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(427), 1\9844_2.fw(427), 1\9844_3.fw(427), 1\9844_4.fw(427), 1\9844_5.fw(427), 1\9844_6.fw(427) Version 2.8.0.0: ID: 619145 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619180 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(426), 1\9844_2.fw(426), 1\9844_3.fw(426), 1\9844_4.fw(426), 1\9844_5.fw(426), 1\9844_6.fw(426) Version 2.7.0.0: ID: 586760 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424), 1\9844_5.fw(424), 1\9844_6.fw(424) Version 2.6.0.0: ID: 574935 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423) Version 2.5.6.0: ID: 565090 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422) Version 2.5.5.0: ID: 551120 Startup time optimizations Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421) Version 2.5.4.0: ID: 540315 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419) Version 2.5.3.0: ID: 523470 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417) Version 2.5.2.0: ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415) Version 2.5.0.0: ID: 468060 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468065 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468070 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468530 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413) Version 2.3.0.0: ID: 454760 AS, System Designersupport: cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No ID: 460105 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460225 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466675 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411) Version 2.2.1.0: ID: 449590 Error when running X20BC8084 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401) Version 2.2.0.0: ID: 439100 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439205 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400) Version 2.1.0.0: ID: 404490 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300) Version 2.0.0.0: ID: 390280 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210) Version 1.3.7.0: ID: 376980 With special constructions it could be that stations will be lost. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174) Version 1.3.6.0: ID: 326655 Link-Selektor funktion upgraded Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169) Version 1.3.5.0: ID: 310790 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311025 / Support ID:400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168) Version 1.3.4.0: ID: 305155 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there wasa high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167) Version 1.3.3.0: ID: 298990 / Support ID: 400090781 Problem withFW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165) Version 1.3.2.0: ID: 289020 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 291455 Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164) Version 1.3.0.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277180 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277750 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160) Version 1.2.1.0: ID: 271200 Upgraded Kabelredundanz supportHardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154) Version 1.2.0.0: ID: 265540 Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved - optimation of Kabelredundancy (Link Selector) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h, 2000h/9 and 20F0h/31 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.9.0: ID: 220450 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization didnot work correctly (A&P 218765) - Network-Failure-Detection did not workwhen BC_RedundancyTxMode_U8 = 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.8.0: ID: 218545 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(145) Version 1.0.4.0: ID: 183390 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(141) Version 1.0.3.0: ID: 173290 First version of the buscontroller with cable redundancy Channel description changed: No Configuration description changed: No Firmwarechanged: No Firmware: 1\9844_1.fw(138) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.12.0.0 | * | 23/07/2021 | 2 Mo | EXE | AS4_HW_X20BC8084.exe | |
Description |
V4.0 HW Upgrade (X20BC8084) Revision information X20BC8084 Version 2.12.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 2.11.0.0: ID: 664370 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664375 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665750 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665835 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666195 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(430), 1\9844_2.fw(430), 1\9844_3.fw(430), 1\9844_4.fw(430), 1\9844_5.fw(430), 1\9844_6.fw(430), 1\9844_7.fw(430) Version 2.10.0.0: ID: 647935 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(428), 1\9844_2.fw(428), 1\9844_3.fw(428), 1\9844_4.fw(428), 1\9844_5.fw(428), 1\9844_6.fw(428), 1\9844_7.fw(428) Version 2.9.0.0: ID: 624085 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629010 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629075 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629160 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(427), 1\9844_2.fw(427), 1\9844_3.fw(427), 1\9844_4.fw(427), 1\9844_5.fw(427), 1\9844_6.fw(427) Version 2.8.0.0: ID: 619145 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619180 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(426), 1\9844_2.fw(426), 1\9844_3.fw(426), 1\9844_4.fw(426), 1\9844_5.fw(426), 1\9844_6.fw(426) Version 2.7.0.0: ID: 586760 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424), 1\9844_5.fw(424), 1\9844_6.fw(424) Version 2.6.0.0: ID: 574935 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423) Version 2.5.6.0: ID: 565090 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422) Version 2.5.5.0: ID: 551120 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421) Version 2.5.4.0: ID: 540315 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419) Version 2.5.3.0: ID: 523470 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417) Version 2.5.2.0: ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415) Version 2.5.0.0: ID: 468060 /Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468065 optimization of X2X FW updates Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 468070 / Support ID: 400177243 X2X FW update of severalX2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468530 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413) Version 2.3.0.0: ID: 454760 AS, System Designer support: cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No ID: 460105 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-oncycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460225 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466675 Module documentation revised Data sheet V 2.32 Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411) Version 2.2.1.0: ID: 449590 Error when running X20BC8084 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401) Version 2.2.0.0: ID: 439100 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439205 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400) Version 2.1.0.0: ID: 404490 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware:1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300) Version 2.0.0.0: ID: 390280 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210) Version 1.3.7.0: ID: 376980 With special constructions it could be that stations will be lost. Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174) Version 1.3.6.0: ID: 326655 Link-Selektor funktion upgraded Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169) Version 1.3.5.0: ID: 310790 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311025 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168) Version 1.3.4.0: ID: 305155 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communicationlost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167),1\9844_3.fw(167) Version 1.3.3.0: ID: 298990 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165) Version 1.3.2.0: ID: 289020 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 291455 Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164) Version 1.3.0.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277180 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277750 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160),1\9844_3.fw(160) Version 1.2.1.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154) Version 1.2.0.0: ID: 265540 Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved - optimation of Kabelredundancy (Link Selector) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h, 2000h/9 and 20F0h/31 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.9.0: ID: 220450 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) - Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.8.0: ID: 218545 Extensions and Bugfixes - Firmware-Version is transferred viaIdentResponse in the first 4 bytes of the field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(145) Version 1.0.4.0: ID: 183390 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(141) Version 1.0.3.0: ID: 173290 First version of the buscontroller with cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(138) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.11.0.0 | * | 31/01/2020 | 2 Mo | EXE | AS4_HW_X20BC8084.exe | |
Description |
V4.0 HW Upgrade (X20BC8084) Revision information X20BC8084 Version 2.11.0.0: ID: 664370 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664375 Adaptationsfor Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665750 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665835 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666195 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(430), 1\9844_2.fw(430), 1\9844_3.fw(430), 1\9844_4.fw(430), 1\9844_5.fw(430), 1\9844_6.fw(430), 1\9844_7.fw(430) Version 2.10.0.0: ID: 647935 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(428), 1\9844_2.fw(428), 1\9844_3.fw(428), 1\9844_4.fw(428), 1\9844_5.fw(428), 1\9844_6.fw(428), 1\9844_7.fw(428) Version 2.9.0.0: ID: 624085 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629010 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629075 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 629160 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(427), 1\9844_2.fw(427), 1\9844_3.fw(427), 1\9844_4.fw(427), 1\9844_5.fw(427), 1\9844_6.fw(427) Version 2.8.0.0: ID: 619145 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619180 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(426), 1\9844_2.fw(426), 1\9844_3.fw(426), 1\9844_4.fw(426), 1\9844_5.fw(426), 1\9844_6.fw(426) Version 2.7.0.0: ID: 586760 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424), 1\9844_5.fw(424), 1\9844_6.fw(424) Version 2.6.0.0: ID: 574935 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423) Version 2.5.6.0: ID: 565090 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422) Version 2.5.5.0: ID: 551120 Startup time optimizations Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421) Version 2.5.4.0: ID: 540315 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419) Version 2.5.3.0: ID: 523470 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417) Version 2.5.2.0: ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415) Version 2.5.0.0: ID: 468060 / Support ID: 400178654 Safetymodules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468065 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468070 / SupportID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468530 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413) Version 2.3.0.0: ID: 454760 AS, System Designer support:cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No ID: 460105 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460225 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466675 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411) Version 2.2.1.0: ID: 449590 Error when running X20BC8084 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401) Version 2.2.0.0: ID: 439100 / Support ID: 400150496 I/O modules behind POWERLINK bus controllersno longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439205 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode aftermultiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400) Version 2.1.0.0: ID: 404490 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unpluggedon the end of the X2XLink thediagnostic data point "StationAtBusEnd" die notchange. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300) Version 2.0.0.0: ID: 390280 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210) Version 1.3.7.0: ID: 376980 With specialconstructions it could be that stations will be lost. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174) Version 1.3.6.0: ID: 326655 Link-Selektor funktion upgraded Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169),1\9844_3.fw(169) Version 1.3.5.0: ID: 310790 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311025 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168) Version 1.3.4.0: ID: 305155 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167) Version 1.3.3.0: ID: 298990 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165) Version 1.3.2.0: ID: 289020 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 291455 Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164) Version 1.3.0.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277180 Support of 'Multiple AsynchronousSend' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277750 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160) Version 1.2.1.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154) Version 1.2.0.0: ID: 265540 Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved - optimation of Kabelredundancy (Link Selector) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h, 2000h/9 and20F0h/31 Channel description changed: Yes Configuration descriptionchanged: Yes Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.9.0: ID: 220450 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not workcorrectly (A&P 218765) - Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.8.0: ID: 218545 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(145) Version 1.0.4.0: ID: 183390 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(141) Version 1.0.3.0: ID: 173290 First version of the buscontroller with cable redundancy Channel descriptionchanged: No Configuration description changed: No Firmware changed:No Firmware: 1\9844_1.fw(138) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.10.0.0 | * | 10/07/2019 | 2 Mo | EXE | AS4_HW_X20BC8084.exe | |
Description |
V4.0 HW Upgrade (X20BC8084) Revision information X20BC8084 Version 2.10.0.0: ID: 647935 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(428), 1\9844_2.fw(428), 1\9844_3.fw(428), 1\9844_4.fw(428), 1\9844_5.fw(428), 1\9844_6.fw(428),1\9844_7.fw(428) Version 2.9.0.0: ID: 624085 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629010 Ring redundancy: Cannot address the CN that closes the ring Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 629075 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629160 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(427), 1\9844_2.fw(427), 1\9844_3.fw(427), 1\9844_4.fw(427), 1\9844_5.fw(427), 1\9844_6.fw(427) Version 2.8.0.0: ID: 619145 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619180 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(426), 1\9844_2.fw(426), 1\9844_3.fw(426), 1\9844_4.fw(426), 1\9844_5.fw(426), 1\9844_6.fw(426) Version 2.7.0.0: ID: 586760 / Support ID: 400241376 Temporary toggling ofdata point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424),1\9844_5.fw(424), 1\9844_6.fw(424) Version 2.6.0.0: ID: 574935 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423) Version 2.5.6.0: ID: 565090 Optimization the boot up for hardware variant5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422) Version 2.5.5.0: ID: 551120 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421) Version 2.5.4.0: ID: 540315 /Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419) Version 2.5.3.0: ID: 523470 / Support ID: 400205694 safety modules notswitching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417) Version 2.5.2.0: ID: 493885 / Support ID:400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415) Version 2.5.0.0: ID: 468060 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468065 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468070 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468530 CiR support Channel description changed: No Configuration description changed: Yes Firmwarechanged: No Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413) Version 2.3.0.0: ID: 454760 AS, System Designer support: cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No ID: 460105 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes ID: 460225 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 466675 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411) Version 2.2.1.0: ID: 449590 Error when running X20BC8084 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401) Version 2.2.0.0: ID: 439100 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439205 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400) Version 2.1.0.0: ID: 404490 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300) Version 2.0.0.0: ID: 390280 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210) Version 1.3.7.0: ID: 376980 With special constructions it could be that stations will be lost. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174) Version 1.3.6.0: ID: 326655 Link-Selektor funktion upgraded Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169) Version 1.3.5.0: ID: 310790 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311025 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168) Version 1.3.4.0: ID: 305155 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a highload on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronouscommunication caused the safety-IO to stop. Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167) Version1.3.3.0: ID: 298990 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165) Version 1.3.2.0: ID: 289020 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 291455 Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164) Version 1.3.0.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277180 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277750 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160) Version1.2.1.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154) Version 1.2.0.0: ID: 265540 Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved - optimation of Kabelredundancy (Link Selector) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h, 2000h/9 and 20F0h/31 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.9.0: ID: 220450 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) - Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.8.0: ID: 218545 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(145) Version 1.0.4.0: ID: 183390 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(141) Version 1.0.3.0: ID: 173290 First version of the buscontroller with cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(138) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.9.0.0 | * | 01/03/2019 | 2 Mo | EXE | AS4_HW_X20BC8084.exe | |
Description |
V4.0 HW Upgrade (X20BC8084) Revision information X20BC8084 Version 2.9.0.0: ID: 624085 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629010 Ring redundancy: Cannot address theCN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629075 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629160 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(427), 1\9844_2.fw(427), 1\9844_3.fw(427), 1\9844_4.fw(427), 1\9844_5.fw(427), 1\9844_6.fw(427) Version 2.8.0.0: ID: 619145 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 619180 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(426), 1\9844_2.fw(426), 1\9844_3.fw(426), 1\9844_4.fw(426), 1\9844_5.fw(426), 1\9844_6.fw(426) Version 2.7.0.0: ID: 586760 /Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424), 1\9844_5.fw(424), 1\9844_6.fw(424) Version 2.6.0.0: ID: 574935 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423) Version 2.5.6.0: ID: 565090 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422) Version 2.5.5.0: ID: 551120 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421) Version 2.5.4.0: ID: 540315 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419),1\9844_3.fw(419), 1\9844_4.fw(419) Version 2.5.3.0: ID: 523470 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417) Version 2.5.2.0: ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415) Version 2.5.0.0: ID: 468060 / Support ID: 400178654 Safety modules in connection withPLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468065 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468070 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 468530 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413) Version 2.3.0.0: ID: 454760 AS, System Designer support: cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No ID: 460105 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460225 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466675 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411) Version 2.2.1.0: ID: 449590 Error when running X20BC8084 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401) Version 2.2.0.0: ID: 439100 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439205 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400),1\9844_3.fw(400) Version 2.1.0.0: ID: 404490 X2XLink-BC:StationAtBusEnd does not change, when empty backplanes are addedor removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data pointdie change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is suppliedwith power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300) Version 2.0.0.0: ID: 390280 / Support ID: 400129274 Uncommon X2Xsettings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210) Version 1.3.7.0: ID: 376980 With special constructions it could be that stations will be lost. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174) Version 1.3.6.0: ID: 326655 Link-Selektor funktion upgraded Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169) Version 1.3.5.0: ID: 310790 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accoredafter PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311025 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168) Version 1.3.4.0: ID: 305155 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167) Version 1.3.3.0: ID: 298990/ Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165) Version 1.3.2.0: ID: 289020 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 291455 Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164) Version 1.3.0.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277180 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277750 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160) Version 1.2.1.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154) Version 1.2.0.0: ID: 265540 Optimation of Kabelredundancy (Link Selector); Update behavior on X2X bus improved - optimation of Kabelredundancy (Link Selector) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h, 2000h/9 and 20F0h/31 Channel description changed: Yes Configuration description changed: Yes Firmwarechanged: Yes Firmware: 1\9844_2.fw(146) Version 1.0.9.0: ID: 220450 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) - Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.8.0: ID: 218545 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(145) Version 1.0.4.0: ID: 183390 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filterand corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(141) Version 1.0.3.0: ID: 173290 First version of the buscontroller with cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(138) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.8.0.0 | * | 05/12/2018 | 2 Mo | EXE | AS4_HW_X20BC8084.exe | |
Description |
V4.0 HW Upgrade (X20BC8084) Revision information X20BC8084 Version 2.8.0.0: ID: 619145 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619180 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(426), 1\9844_2.fw(426), 1\9844_3.fw(426), 1\9844_4.fw(426), 1\9844_5.fw(426), 1\9844_6.fw(426) Version 2.7.0.0: ID: 586760 / Support ID: 400241376 Temporarytoggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424), 1\9844_5.fw(424), 1\9844_6.fw(424) Version 2.6.0.0: ID: 574935 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423) Version 2.5.6.0: ID: 565090 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422) Version 2.5.5.0: ID: 551120 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421) Version 2.5.4.0: ID: 540315 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419) Version 2.5.3.0: ID: 523470 / Support ID: 400205694 safetymodules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417) Version 2.5.2.0: ID: 493885 /Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415) Version 2.5.0.0: ID: 468060 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints,are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468065 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468070 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468530 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413) Version 2.3.0.0: ID: 454760 AS, System Designer support: cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No ID: 460105 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers nolonger achieving Operationalmode after multiple power-on cycles Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 460225 / Support ID: 400150525 Error 114834"Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLXhinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466675 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411) Version 2.2.1.0: ID: 449590 Error when running X20BC8084 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401) Version 2.2.0.0: ID: 439100 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439205 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400) Version 2.1.0.0: ID: 404490 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300) Version 2.0.0.0: ID: 390280 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of buscontroller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210) Version 1.3.7.0: ID: 376980 With special constructions it could be that stations will be lost. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174) Version 1.3.6.0: ID: 326655 Link-Selektor funktion upgraded Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169) Version 1.3.5.0: ID: 310790 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311025 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168) Version 1.3.4.0: ID: 305155 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167) Version 1.3.3.0: ID: 298990 / Support ID: 400090781 Problemwith FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165) Version 1.3.2.0: ID: 289020 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 291455 Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164) Version 1.3.0.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277180 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277750 NewX2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160) Version 1.2.1.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154) Version 1.2.0.0: ID: 265540 Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved - optimation of Kabelredundancy (Link Selector) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h, 2000h/9 and 20F0h/31 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.9.0: ID: 220450 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) - Network-Failure-Detection did notwork when BC_RedundancyTxMode_U8 = 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.8.0: ID: 218545 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(145) Version 1.0.4.0: ID: 183390 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(141) Version 1.0.3.0: ID: 173290 First version of the buscontroller with cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(138) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.7.0.0 | * | 17/04/2018 | 2 Mo | EXE | AS4_HW_X20BC8084.exe | |
Description |
V4.0 HW Upgrade (X20BC8084) Revision information X20BC8084 Version 2.7.0.0: ID: 586760 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(424), 1\9844_2.fw(424), 1\9844_3.fw(424), 1\9844_4.fw(424), 1\9844_5.fw(424), 1\9844_6.fw(424) Version 2.6.0.0: ID: 574935 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423) Version 2.5.6.0: ID: 565090 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422) Version 2.5.5.0: ID: 551120 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421) Version 2.5.4.0: ID: 540315 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419) Version 2.5.3.0: ID: 523470 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417) Version 2.5.2.0: ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASndSDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415) Version 2.5.0.0: ID: 468060 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468065 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468070 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468530 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413) Version 2.3.0.0: ID: 454760 AS, System Designer support: cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No ID: 460105 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longerachieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460225 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466675 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(411),1\9844_2.fw(411), 1\9844_3.fw(411) Version 2.2.1.0: ID: 449590 Error when running X20BC8084 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401) Version 2.2.0.0: ID: 439100 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439205 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400) Version 2.1.0.0: ID: 404490 X2XLink-BC: StationAtBusEnd does not change, when emptybackplanes are addedor removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implementedto update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300) Version 2.0.0.0: ID: 390280 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210) Version 1.3.7.0: ID: 376980 With special constructions it could be that stations will be lost. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174) Version 1.3.6.0: ID: 326655 Link-Selektor funktion upgraded Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169) Version 1.3.5.0: ID: 310790 / SupportID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311025 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168) Version 1.3.4.0: ID: 305155 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was ahigh load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167) Version 1.3.3.0: ID: 298990 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update ofIO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165) Version 1.3.2.0: ID: 289020 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 291455 Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164) Version 1.3.0.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277180 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277750 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160) Version 1.2.1.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(154),1\9844_2.fw(154) Version 1.2.0.0: ID: 265540 Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved - optimation of Kabelredundancy (Link Selector) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h, 2000h/9 and 20F0h/31 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.9.0: ID: 220450 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) - Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.8.0: ID: 218545 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first4 bytes of the field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(145) Version1.0.4.0: ID: 183390 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(141) Version 1.0.3.0: ID: 173290 First version of the buscontroller with cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(138) |
|||||
Version | Langue | Système d'exploitation | Date | Taille | Type | Téléchargement |
2.6.0.0 | * | 02/02/2018 | 2 Mo | EXE | AS4_HW_X20BC8084.exe | |
Description |
V4.0 HW Upgrade (X20BC8084) Revision information X20BC8084 Version 2.6.0.0: ID: 574935 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(423), 1\9844_2.fw(423), 1\9844_3.fw(423), 1\9844_4.fw(423), 1\9844_5.fw(423), 1\9844_6.fw(423) Version 2.5.6.0: ID: 565090 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(422), 1\9844_2.fw(422), 1\9844_3.fw(422), 1\9844_4.fw(422), 1\9844_5.fw(422) Version 2.5.5.0: ID: 551120 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(421), 1\9844_2.fw(421), 1\9844_3.fw(421), 1\9844_4.fw(421), 1\9844_5.fw(421) Version2.5.4.0: ID: 540315 / Support ID: 400202320 BC sporadically notgoing into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419),1\9844_4.fw(419) Version 2.5.3.0: ID: 523470 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417) Version 2.5.2.0: ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415) Version 2.5.0.0: ID: 468060 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468065 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468070 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468530 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413) Version 2.3.0.0: ID: 454760 AS, System Designer support: cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No ID: 460105 / Support ID: 400168329 I/O modules behind POWERLINKbus controllers no longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460225 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466675 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411) Version 2.2.1.0: ID: 449590 Error when running X20BC8084 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401) Version 2.2.0.0: ID: 439100 / Support ID: 400150496 I/O modulesbehind POWERLINK bus controllers no longer achieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439205 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longerachieving Operationalmode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400) Version 2.1.0.0: ID: 404490 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300) Version 2.0.0.0: ID: 390280 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210) Version 1.3.7.0: ID: 376980 With special constructions it could be that stations willbe lost. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174) Version 1.3.6.0: ID: 326655 Link-Selektor funktion upgraded Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169) Version 1.3.5.0: ID: 310790 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311025 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168) Version 1.3.4.0: ID: 305155 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication tothe buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167) Version 1.3.3.0: ID: 298990 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165) Version 1.3.2.0: ID: 289020 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 291455 Upgrade1.3.1.0 on X20BC8084 to revision E0 may cause problems Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164) Version 1.3.0.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277180 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277750 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160) Version 1.2.1.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154) Version 1.2.0.0: ID: 265540 Optimation of Kabelredundancy (Link Selector) ; Update behavioron X2X bus improved - optimation of Kabelredundancy (Link Selector) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h, 2000h/9 and 20F0h/31 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.9.0: ID: 220450 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) - Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.8.0: ID: 218545 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(145) Version 1.0.4.0: ID: 183390 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(141) Version 1.0.3.0: ID: 173290 First version of the buscontroller with cable redundancy Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(138) |